LINE
ITEM # |
Please click on photo
for a larger view! |
QTY & UOM |
DESCRIPTION |
|
1 |

08-01-959 |
80 EA |
CONNECTOR, WEDGE TAP, 2-PC AL COMPRESS TAP CONN FOR AL TO AL OR AL
TO CU, CONSIST OF AL SPRING C MEMBER, AL ALLOY WDG LABELED, COLOR
CODED ANSI C119.4, CL A, CL 3. MAIN 1033.5 45/76 ACSR; TAP-1033.5
45/7 ACSR, MAIN-1192.5 45/7 ACSR; TAP-1033.5 45/7 AC
Mfg ID/Item ID: TYCOELECT 602300-2
08-01-959 |
|
2 |

08-02-001 |
2 EA |
ADAPTER, REDUCER, TRUNION, DECORATIVE, 7IN TO 3IN FOR EDGE-WATER P.T,
ORNAMENTAL POLE, CAST ALUMINUM OCTAGONAL WITH (4) 1/4" SS
ATTACHMENT SET SCREWS, EXTENDS POLE HEIGHT APPROX, 4-3/8" PRIMER
COATED UNLESS OTHER-WISE SPECIFIED WITH ORDER.
Mfg ID/Item ID: n/a
08-02-001 |
|
3 |

08-02-989 |
12 EA |
REFRACTOR, ACRYLIC, ONE PIECE REPLACEMENT, FOR LANTERN POST TOP
LUMINAIRE WITH VERTICAL BASE MOUNTED TYPE III MERCURY VAPOR LAMPS
Mfg ID/Item ID: GELIGHTING 35-963160-03
08-02-989 |
|
4 |

08-05-145 |
5 EA |
LUMINAIRE, POST TOP, EDISON, HPS, 100 WATT, IES TYPE III
DISTRIBUTION, POLYCARBONATE GLOBE, 120V REGULATED BALLAST, PE
RECEPTACLE ON GLOBE EA 5.0000 GELIGHTING AM910S1H2C4GN015
Mfg ID/Item ID: GELIGHTING AM910S1H2C4GN015
08-05-145 |
|
5 |

08-07-265 |
1,800 EA |
BOLT, UPSET, DOUBLE, GALVANIZED STEEL, 5/8IN DIA X 12IN LONG includes
SQUARE NUT, ROUND WASHER, COTTER KEY ON SHORT END, SQUARE
NUT AND M-F LOCKNUT ON LONG END. PER ANSI STANDARD C135.13. REQUIRES
I-25SPOOL INSULATOR.
Mfg ID/Item ID: ABCHANCE 7832, COOPERPOW DC3E14,
JOSLYN J239808-07-265 |
|
6 |
 
08-07-653 |
4 EA |
SWITCH, PREASSEMBLED, THREE PHASE, GROUP OPERATED, LOADBREAK, 23,
34.5 KV, 200 KV BIL, 600 AMP, FITTED WITH LOADBREAK INTERRUPTERS,
HORIZONTAL UPRIGHT MOUNTING CONFIGURATION, SHALL BE PREASSEMBLED
AND PREALIGNED ON A SINGLE MEMBER STEEL OR ALUMINUM BAS
Mfg ID/Item ID: SCELECTRIC 137464R2
08-07-653 |
|
7 |

08-08-147 |
54 EA |
HAT, HARD, V-GARD, GAS, ORANGE, SMALL 6" - 7-1/8", W/STAZ-ON SUSP,
SLOTTED, W/FRONT NIMOGAS FLAME LOGO, 1" X 4" BLUE REFLECT STRIPES,
GAS FLAME ON SIDES, BACK, BLACK SAFETY EXCELLENCE STARTS HERE LOGO
ON BACK, PER ANSI Z89.1 CLASS B
Mfg ID/Item ID: MSA A-1-489366G (GAS)
08-08-147 |
|
8 |

08-08-978 |
10 EA |
SWITCH, ELECTROSWITCH, TYPE LSR-1, 48 VDC WITH INTERPOSING RELAY,
OPERATING COIL C RATED AT 48 VDC, SERIES 24, PANEL MOUNT, ESCUTCHEON
CODE 10D-2C22H ENGRAVED RECLOSING SWITCH, FOR 1/8" THICK PANELS
Mfg ID/Item ID: ELECSWITCH 9203CD
08-08-978 |
|
9 |

08-09-002 |
63 EA |
LIGHT, HARDHAT, SAFETY, WITH VELCRO STRIPS, WITHOUT AA BATTERIES
Mfg ID/Item ID: FULTONIND 6200-B
08-09-002 |
|
10 |

08-09-687 |
35 EA |
INDICATOR, FAULT CIRCUIT, STROBE, MANUAL RESET, 6 HOUR TIME DELAY,
100 AMP.
Mfg ID/Item ID: POWERDELV
27-0501-002-100A-6H
08-09-687 |
|
11 |

08-09-689 |
98 EA |
INDICATOR, FAULT CIRCUIT, STROBE, MANUAL RESET, 6 HOUR TIME DELAY,
400 AMP.
Mfg ID/Item ID: POWERDELV 27-0501-002-4006
08-09-689 |
|
12 |

08-09-846 |
196 EA |
TERMINATION, KIT, PREMOLDED, 600A, 15KV, 500 KCMIL, DESIGNED FOR
TERMINATING 500 KCMIL ALUMINUM CONCENTRIC NEUTRAL PRIMARY CABLE,
ITEM UC11GG WITH AN INSULATION O.D. OF 1.22 pm .030", THE KIT SHALL
INCLUDE A STRESS CONE, 4 SKIRTS AND SILICONE GREASE
Mfg ID/Item ID: CHARDON 9U08KYX004,
ELASTIMOLD 35MTGI-HJ-4-CS357
08-09-846 |
|
13 |

08-10-095 |
115 EA |
CONNECTOR, ALUMINUM TAP, 336.4 TO NO.1/0
Mfg ID/Item ID: CONNECPROD 350121
08-10-095 |
|
14 |

08-10-194 |
1,700 EA |
REDUCER, PVC, 2" X 1 1/4"
Mfg ID/Item ID: CARLON E950JG
08-10-194 |
|
15 |

08-10-507 |
1,180 EA |
BOOT, INSULATING, SECONDARY CONNECTOR, CLEAR
Mfg ID/Item ID: HOMAC ZVW3033-USLRBOOT
08-10-507 |
|
16 |

10-08-082 |
29 CN |
PAINT, SPRAY, CHALK BASED YELLOW SPRAY MATERIAL WITH VERTICAL SPRAY
NOZZLE, MAY BE USED WITH HANDLE APPLICATOR, ITEM UP11A. SUPPLIED IN
13.5 OZ (NET WEIGHT) 17 OZ GROSS WEIGHT(NET PLUS PROPELLENT) AEROSOL
CANS
Mfg ID/Item ID: AERVOEPAC 218 (17 OZ.),
FOXVALLEY -- (13.5 OZ.)
10-08-082 |
|
17 |

15-41-607 |
5 EA |
GASKET, CORRUGATED MONEL DWG SKE1790 STATIONARY HEAD COVER F/GRISCOM
RUSSELL 24-6-324 TYPE M SU FEEDWATER S/N 76495 UNITS 1, 2 1ST STAGE
HEATER
Mfg ID/Item ID:
n/a
15-41-607 |
|
18 |

20-03-013 |
8 EA |
FUSE, NETWORK PROTECTOR, LOW VOLTAGE, NON-EXPULSION, SILVER, SAND
TYPE FUSE FOR USE WITH WESTINGHOUSE TYPE CMD NETWORK PROTECTOR ONLY,
ITEM UP2 OR UP3. PROTECTOR CURRENT RATING 1875
Mfg ID/Item ID: CURLEE NPL140D318GO1,
CURRYOIL NPL140D318GO1
20-03-013 |
|
19 |

20-03-014 |
2 EA |
FUSE, NETWORK PROTECTOR, LOW VOLTAGE, NON-EXPULSION, SILVER, SAND
TYPE FUSE FOR USE WITH WESTINGHOUSE TYPE CMD NETWORK PROTECTOR ONLY,
ITEM UP2 OR UP3. PROTECTOR CURRENT RATING 2825
Mfg ID/Item ID: CURTISIND NPL140D318GO2
20-03-014 |
|
20 |

20-04-647 |
3 EA |
SWITCH, 34.5KV, 600A, SINGLE POLE, OPER WITH POST TYPE GRAY GLAZE
COLOR INSULATOR WITH 2 HOLE TERMINAL PAD 9/16" HOLES ON 1 3/4I"
CENTER, NEMA CAT 55030
Mfg ID/Item ID:
n/a
20-04-647 |
|
21 |

20-05-601 |
8,500 EA |
COVER, INSULATING, SNAP-ON, POLYETHYLENE, BLACK, 5/8I" AND BG DIE
COMPRESSION TAP CONNECTORS.
Mfg ID/Item ID: ANDERSONE SEC-4, BLACKBURN
C2
20-05-601 |
|
22 |

20-06-022 |
9 EA |
ARRESTER, SURGE, INTERMEDIATE CLASS, POLYMER HOUSED, MOV TYPE, 45KV.
DUTY CYCLE RATING. 36.5KV. MCOV.
Mfg ID/Item ID: OHIOBRASS 300036-3002
20-06-022 |
|
23 |

20-06-023 |
3 EA |
ARRESTER, SURGE, 22KV, INTERMEDIATE CLASS, METAL OXIDE, MAXIMUM
CONTINUOUS OPERATING VOLTAGE, 22KV RMS, TYPE VI
Mfg ID/Item ID: OHIOBRASS 218022
20-06-023 |
|
24 |

20-06-025 |
10 EA |
ELBOW, LIGHTNING ARRESTOR, 27 KV, DISTRIBUTION CLASS, METAL-OXIDE
TYPE SURGE ARRESTOR, 27 KV (22KV MVOV) SHIELDED ELBOW HOUSED IN
ACCORDANCE WITH ANSI C62.11 AND ANSI/IEEE 386, FURNISHED WITH A BARE
37" LONG NO.6 AWG STRANDED COPPER GROUNDING CABLE
Mfg ID/Item ID: ELASTIMOLD 375ESA-27,
JOSLYN 8132B1027J011
20-06-025 |
|
25 |

20-06-257 |
6 EA |
ARRESTER, SURGE, INTERMEDIATE CLASS, POLYMER HOUSED, MOV TYPE, 36KV.
Mfg ID/Item ID: GEELECDIST 9LA2F62
20-06-257 |
|
26 |

20-06-276 |
7 EA |
ARRESTER, SURGE, 34.5KV, LIGHTNING, THYRITE, LESS MOUNTING BRACKET
Mfg ID/Item ID: GEELECDIST 9LA2G61
20-06-276 |
|
27 |

20-07-540 |
31 EA |
SUPPORT, BUS, TUBE/CABLE, 3" B.C., F/ONE 2" FLAT ALUMINUM BAR FLAT
TO INSULATOR. FURNISH CAP SCREWS.
Mfg ID/Item ID: ANDERSONE ABHX-20-3-1/4,
BURNDY HHHR12-3W, DOSSERT SHH 2-3-AA, FRANKEL AKY-2-2-3, ROYALSWIT
AFH-3-54621
20-07-540 |
|
28 |

20-09-784 |
75 EA |
FUSE, LINK, UNIVERSAL, 140 AMP, K TYPE, OUTDOOR. SUPPLIED WITH
REMOVABLE BUTTONHEAD AND DOUBLE PIGTAIL. ANSI C37.42.
Mfg ID/Item ID: ABCHANCE (O) M140 KA23,
ABCHANCE M140KA23T, COOPERPOW (O) FL3K140, COOPERPOW FL43K140,OZGEDNEY SGN-125
20-09-784 |
|
29 |

20-14-076 |
20 EA |
INSERT, PLUG, LOADBREAK BUSHING, 200 AMP, 21.1/36.6 KV, FOR USE AS
AN INTERFACE BETWEEN AN APPARATUS BUSHING WELL AND A LOADBREAK ELBOW
ITEM UR90 OR OTHER LOADBREAK ACCESSORIES, TO BE IN ACCORDANCE WITH
ANSI/IEEE 386
Mfg ID/Item ID: ELASTIMOLD 3701A3
20-14-076 |
|
30 |


21-04-077 |
37 EA |
SPLICE, HEAT SHRINK KIT, STRAIGHT CABLE SPLICE-35KV DESIGNED FOR
SPLICING TOGETHER TWO 750 KCMIL COPPER CONCENTRIC NEUTRAL
UNDERGROUND PRIMARY CABLES, ITEM UC35HJ, THE KIT SHALL BE
INDIVIDUALLY BOXED
Mfg ID/Item ID: RAYCHEM HVS-3512S-J
21-04-077 |
|
31 |

21-04-285 |
9 EA |
KIT, CABLE JOINT 350M GF FOR 3C-250 MCM 34.5KV GAS FILLED CABLE GE
13B372
Mfg ID/Item ID:
n/a
21-04-285 |
|
32 |

20-14-307 |
568 EA |
SPLICE, COMPRESSION, STANDARD, FOR 4(6/1) OR (7/1)ACSR TO
SAME, 90PC TENSION
Mfg ID/Item ID: BURNDY YDS4RL, HOMAC GS467
20-14-307 |
|
33 |

20-14-329 |
1,973 EA |
SPLICE, COMPRESSION, STANDARD, 2(6/1) TO SAME, 90PC TENSION, FOR
ACSR
Mfg ID/Item ID: BURNDY YDS2RL, HOMAC DS26
20-14-329 |
|
34 |

20-14-332 |
1,267 EA |
SPLICE, COMPRESSION, STANDARD, 1/0 AWG AAAC, ACSR (6/1), RATED 90PC
BREAKING STRENGTH
Mfg ID/Item ID: ALCOACOND (O)7511-453,
BURNDY YDS25RL,
HOMAC (O)WS-10, HOMAC RS-10
20-14-332 |
|
35 |

20-14-861 |
665 EA |
CONNECTOR, INSUL SECY-XFORMER 1"-14 UNC STUD PH CONN, (1) 5/16"
ALLEN HD SET SCREW POS, 1 STRT LGT TAP POS, DES FOR TERM INSUL CU,
AL SECY, SERV LAT PH CBL WITH A CBL RNG OF NO.6 AWG STRD THRU 350
KCMIL STRD WITH A MAX OD OF .90"
Mfg ID/Item ID: ALCONINC
VBTOT61-350-2SIDC900
CONNECTMFG NSSC350-6BSLDI, UTILCO PTF6-350CJSLDP1
20-14-861 |
|
36 |

20-14-863 |
806 EA |
CONNECTOR, UNINSULATED SECY XFORMER 1"-14 UNC STUD NEUT CONN (1)
5/16" ALLEN HD SET SCR TYP 6 MAIN POSI, ONE STREET LGT TAP POSI
UNINSULATED SECY NEUT CONN DES FOR TERM INSUL, UNINSUL CU, AL SECY,
SERV LATL NEUT CBL WITH A CBL RNG OF NO.6 AWG STRD
Mfg ID/Item ID: ALCONINC BTOT61-350-2SI,
CONNECTMFG NSSM350-6BSLDI, UTILCO PTF6-350JSLDP1
20-14-863 |
|
37 |

20-14-926 |
162 EA |
CONNECTOR, DOUBLE BOLT TYPE 6 POSITION INSUL SECY CONN DES FOR
CONNECTING INSUL CU, AL SECY, SERV LAT CBL WITH A CBL RNG OF NO.4
AWG SOLID THRU 500 KCMIL STRD WITH A MAX INSUL OD OF 1.10", THE CONN WILL ACCOMMODATE A STREET LGT TAP W/THE USE OF A STRE
Mfg ID/Item ID:
n/a
20-14-926 |
|
38 |

20-14-936 |
34 EA |
CONNECTOR, SECONDARY, INSL CAB
Mfg ID/Item ID: CONNECTMFG SSBC750-6DI,
UTILCO (O)PED6-750SSDNMP, UTILCO PED6-750SSDP
20-14-936 |
|
39 |

20-14-951 |
96 EA |
SPLICE, DOUBLE BOLT, INSLN SECY STR
SPLICE, FOR SPLICING 2 INSLN CU /OR ALUM SECY CABLE W/RANGE NO.4 AWG
SOLID THRU 500 KCMIL STRD W/MAX INSLN OD OF 1.10", INSLN SECY STR
SPLICE, DIRECT BURIAL, SERVICE HANDHOLE WHEN OPERATED ON 600 VOLT
SYSTEM, BELOW
Mfg ID/Item ID:
n/a
20-14-951 |
|
40 |

20-18-055 |
15 EA |
FUSE, POWER SM-5 -34.5KV -S C TYPE SM-5, 34.5KV, 300A MAX., POWER
FUSE FOR USE WITH S C TYPE POWER FUSE HOLDER, ITEM F7H, USED IN
CONJUNCTION WITH 34.5KV, PAD-MOUNTED SWITCHGEAR.
Mfg ID/Item ID: SCELECTRIC 264060R4
20-18-055 |